CONTROL PANELS
AS Standard Fire Panels FP-C2 Panel FP-22408 Panel FP-08100 Control Panel FP-08450 Panel

Australian Standard Fire Panels are all compatible with FirePro Generators. The Sigma XT panel has a Gas Card to enable delays and warning signs etc. Can operate as a main FIP or Sub FIP and can interface will all types of AS panels.

Brochure Manual

Can be used as sub-panel or main panel for local protection solutions has monitored circuits, can use LHD, heat or smoke detectors, activate up to 4 FirePro units. • automatic extinguishing • 24vDC Power • signal for fire/fault conditions.

Manual

Vehicle AS 5062 Panel. Features • Monitored Circuits • Various detection devices • Relay for Engine Shutdown • Manual and Automatic Activation • Activate up to 4 FP units • 6-36v DC Compatible • Battery Backup.

Manual Manual Short

Simple NON-Monitored Control Panel can be used in Vehicle or Marine Applications. Can be configured to operate with/without LHD detection. IP65 Rated 12-24vDC. Has inbuilt siren with output available for external siren. Activates up to 4 FP Units.

Manual

Control Panel.Features • Manual or Auto operation • Twin power supply inputs • 2 Detection circuits – works with Thermal ROR, smoke detectors, or LHD • Capable of double knock operation • All circuits monitored • Options for delayed or 2nd shot.

Manual Options

OTHER COMPONENTS
Electronic Signs – AS Fire Panels Detectors FP-08940 Sounder/Strobe Other Signs FP-08800 FirePro Test Simulator

• System Inoperative – WP available
• Fire Alarm – Evacuate Area – WP available
• Fire Alarm – Do Not Enter – WP available

Brochure

• Photo Electric Smoke
• Thermal 60°C ROR (20°C over 1 min) Combo
• Thermal 90°C ROR (20°C over 1 min) Combo
• Operating Voltage 9.5-30vDC

General Marine

• Audible and visual device
• Requires single installation point.
• Operating Voltage 9-28vDC

Manual

These comply to regulations for signage required for Fire Suppression Systems.
 

Marine Vehicle Cabinet

Used in commissioning and testing of the systems. Each system has different requirements for this device – check manual for correct selection.

Manual

FP-09500 Fire Rated Shielded Cable FP-09510 Linear Heat Detection Dust Seals FP-14053 Switch System Cable Looms

Electrical Installations to be completed using
2 Core Screened Fire Rated Cable.
Cable is 2 Hour Fire Rated.

Data Sheet

Linear Heat Detection has conductors in insulation. When heated to specified temperature, the circuit is closed.

Manual

Vinyl Dust Seals are available all Models to protect from dust, vermin and other debris.:

FP-06910 for FP-1200 – 5700
FP-06920 for FP-0100 – 0500
FP-06930 for FP-0040 – 0080

Aluminium Moulded Switch with SS mount. Complete with safety pin to protect against accidental activation.

Data Sheet

Color Coded for easy Installation
IP65 Rated
Supplied to correct lengths.